![]() ![]() I will move on and maybe ask somewhere else. If you dont have much rep power to give, you will not get any good help, sad but true. Im sure there are ppl in this Forum that are able to unpack this somehow but i guess you were right, everyone cares about reputation. However, i havent seen a answer with a solution to this yet. Its just UPX and it should be easy but for some reason it gets complicated if you want to unpack UPX packed AutoIT executables (they just dont work after unpacking). My only goal is to find out why/how i cant/can successfully unpack this. Not really what im looking for but i will give you some rep(dont have much :P) just because you rly tried to help. Otherwise if you decompress with upx only you'll not be able to start the program, re-compiling it from its own script is a solution to your question I guess With it you'll extract the 64 bit script and recompile the program from it's own script. Ok then just decompress standardly with upx -d, then use this script you can find here : Then dump the data.(in the register or data pointed) To unpack crypters, simply set breakpoints on registers.Įach time breakpoint gets hit, check if PE is fully decrypted. Just try to unpack it by yourself and post some explanation or little guide pls. autoit simpleBlog CiudadanosVisibles6 highlightjs map-chat MonoJavaBridge. I have no Idea what i do wrong but im sure there are ppl here that can figure it out. dubbo-remoting Angular Applications priv folly mayfield debug Module Boo. looks fine, no Invalid Imports.Ĩ.Click Fix Dump and select the saved Dumpĩ.Done and it should work now. I decided to use 圆4dbg with the Scylla plugin.ġ.Open the Target with 圆4dbg and run to EntryPointģ.From the JMP, set breakpoint there, run and jmp to the OEPĥ.Open Scylla, copy paste OEP to the OEP Editbox and use "IAT Autosearch" plus "Get Imports"Ħ.Check if there are some Invalid Imports. The stack trace can be explicitly shown using Ctrl+Alt+S and will automatically presented if possible when an error occurs. Keep in mind, it is a 圆4 Executable, which means, we cant use the famous ImportREC Tool. scite-debug generally knows how to interpret a stack trace double-clicking on the required level will put you into that frame and place you at the corresponding source line. If i had to guess, i would say, something is wrong with rebuilding the IAT. I remember using the SciTE editor with AutoIT a long time ago. Ive watched multiple UPX unpacking Guides and it seems very easy but somehow this wont work with the AutoIT UPX packed Version. Awful hard to attach a debugger to a production system. ![]() Start>ProgramFiles>AutoIt >SciTE Script Editor. Bye!")īoth of them can be downloaded from the AutoIT Website. Under What Conditions Should You Test set() and get() Methods. Local $iAnswer = MsgBox(BitOR($MB_YESNO, $MB_SYSTEMMODAL), "AutoIt Example", "This script will run the calculator and type in 2 x 4 x 8 x 16 and then quit. #EndRegion **** Directives created by AutoIt3Wrapper_GUI **** #AutoIt3Wrapper_Outfile_圆4=UPXpacked圆4AutoIT.Exe Code: #Region **** Directives created by AutoIt3Wrapper_GUI **** ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |